Boiler leak and no hot water: valves, tank and coil replaced

Last updated Reviewed by Waseem Shahzad, Lead Technician

Huntington, NYBoiler RepairTechnician: WaseemSeptember 2026

A boiler that had lost hot water and was leaking. We replaced the failed valves, the expansion tank and the leaking domestic hot water coil.

Boiler gauges checked during the repair, Huntington NY
Boiler gauges checked during the repair, Huntington NY
Water feed and relief valve piping on the boiler, Huntington NY
Water feed and relief valve piping on the boiler, Huntington NY
Expansion tank draining during the boiler repair, Huntington NY
Expansion tank draining during the boiler repair, Huntington NY
Old domestic hot water coil removed from the boiler, Huntington NY
Old domestic hot water coil removed from the boiler, Huntington NY

What the homeowner reported

Over a weekend the home lost hot water and the boiler was found shut off. Hot water had come back, but the heat and hot water needed checking.

What we found

Water was overflowing from the boiler and the heat was also not working. The water feed valve, air bleeder, relief valve and expansion tank had all failed, and the domestic hot water coil inside the boiler was leaking.

What we did

Waseem replaced the water feed valve, the air bleeder, the relief valve, the expansion tank and the gauge. Once those repairs were approved and done, he replaced the leaking domestic hot water coil in the boiler.

The result

With the new coil installed, the hot water was working, and the heat was working again.

Job details are from our September 2026 service record for this Huntington home. Customer details are left out.

General information, not details from this job

About boiler hot water coils

Many boilers make the home's hot water with a coil inside the boiler: cold water passes through it and is heated by the boiler water around it. When that coil leaks, domestic water gets into the boiler, the pressure climbs and the relief valve can drip or blow off. Replacing only the valves will not fix it if the coil is the source, which is why the coil is tested as part of a leaking-boiler diagnosis.