Recent K2 Projects on Long Island
Real jobs from our technicians: the town, the system, what we found, what we did and how it turned out.

Heating tune-up on twin 100,000 BTU gas furnaces
Babylon · Heating Tune-Up · October 2026
A heating-season tune-up on two gas furnaces, each rated 100,000 BTU: flame sensors and inducer tubes cleaned, motor amps checked.

Central air replaced, with a new line set and a relocated condenser
Deer Park · AC Installation · October 2026
A cooling system replaced with equipment the homeowner supplied, plus a new line set, return duct changes and a relocated condenser.

Oil furnace replaced with gas heat, central air and a water heater
West Babylon · Heating & Cooling Installation · October 2026
An oil furnace and oil tank removed and replaced with a Goodman gas furnace, central air, a new water heater and a Wi-Fi thermostat.

No heat: expansion tank, relief valve and circulator replaced
East Islip · Heating Repair · October 2026
A new customer with no heat. We replaced the air bleeder, expansion tank, relief valve and circulator pump and tuned up the system.

Noisy furnace: draft motor vibration fixed and flue resealed
Commack · Furnace Repair · October 2026
Loud fan noise traced to a vibrating draft inducer motor. We tightened it, resealed the flue pipe and tuned up the furnace.

One of three boiler zones not heating
Dix Hills · Boiler Repair · October 2026
A three-zone gas boiler with one cold zone. We bled the air from all three zones, replaced the air bleeder and four caps, and cleaned the boiler.

Leaking water heater connection repaired
Dix Hills · Water Heater Repair · October 2026
A leak the homeowner pointed out during another visit. We came back the next day, replaced the leaking coupling and resoldered the joint.

Faulty thermostat replaced with a Nest
Dix Hills · Thermostat Installation · October 2026
The heating checked out fine but the thermostat was not working properly, so we installed a Nest the homeowner supplied.

Oil boiler tune-up before the heating season
Huntington Station · Heating Tune-Up · October 2026
A heating-season tune-up on an oil boiler: new oil filter, a full clean, and the system water drained and refilled.

Oil boiler tune-up with two air bleeders replaced
Stony Brook · Heating Tune-Up · October 2026
A fall tune-up on an oil boiler: burner cleaned, oil filter serviced, two failed air bleeders replaced and the system refilled with fresh water.

Older R-22 system: new capacitor and a cleared drain line
Commack · AC Repair · September 2026
A service call on an older R-22 system: a bad capacitor replaced, refrigerant confirmed good, and a leaking drain line cleared with nitrogen.

Boiler leak and no hot water: valves, tank and coil replaced
Huntington · Boiler Repair · September 2026
A boiler that had lost hot water and was leaking. We replaced the failed valves, the expansion tank and the leaking domestic hot water coil.

Air conditioner compressor replaced
East Northport · AC Repair · September 2026
A failed compressor replaced in an American Standard condenser, then the system pressure tested, evacuated and recharged.

AC leaking water: drain line cleared with nitrogen
Melville · AC Repair · September 2026
Water was leaking from the air handler. The condensate drain line was not draining; we cleared it with nitrogen and the system was working again.

Frozen AC coil traced to an open condensate drain line
Northport · AC Repair · August 2026
No cooling from a frozen indoor coil. An uncovered drain line was drawing air into the unit; we fixed it, let the coil thaw and finished the next morning.

Second-floor AC not cooling: ECM blower motor replaced
Greenlawn · AC Repair · August 2026
A 28-year-old second-floor system stopped cooling. The ECM blower motor had failed; we sourced a new one, installed it and checked the amps.

No cooling: leaking Schrader core replaced and both coils cleaned
Deer Park · AC Repair · August 2026
A no-cooling call. The suction service valve had a leaking Schrader core, and both coils were dirty. We replaced the core and cleaned both coils.

AC leaking water: clogged drain cleared and the unit leveled
Bellmore · AC Repair · August 2026
An air conditioner was leaking water. The drain line was clogged and the indoor unit was not level; we cleared the line with nitrogen and leveled it.

First cleaning in years finds a weak capacitor
Bay Shore · AC Tune-Up · July 2026
A 16-year-old air conditioner that had never been cleaned got a full tune-up. A capacitor reading low on the compressor side was replaced.

Goodman condenser fan motor and capacitor replaced
Commack · AC Repair · July 2026
On a Goodman first-floor system, a failed condenser fan motor was replaced along with the capacitor, and the condenser pad was replaced.

No cooling: capacitor replaced and both coils chemically cleaned
Deer Park · AC Repair · July 2026
A no-cooling call: a bad capacitor and a very dirty condenser. We replaced the capacitor and chemically cleaned the evaporator and condenser coils.

Upstairs not cooling: packed condenser coil cleaned
Hauppauge · AC Repair · July 2026
The upstairs stayed at 77 degrees with the thermostat at 68. The condenser coil was packed with dirt, and the hydronic heat was also on.

No hot water: gas water heater replaced, plus a new AC capacitor
East Meadow · Water Heater Replacement · July 2026
A no-hot-water call. The gas water heater had failed, so we replaced it with a new 40-gallon direct-vent unit and also replaced an AC capacitor.

Warm air from a newer AC: dirty filter and a loose TXV
Lake Ronkonkoma · AC Repair · June 2026
A system installed in 2025 was blowing warm air. We replaced a dirty filter and fixed a loose thermostatic expansion valve.

Basement mini-split: restarted, outdoor coil cleaned
Dix Hills · Mini-Split Service · June 2026
A basement mini-split had stopped working. It started normally on the visit; we cleaned the dirty outdoor coil and confirmed the refrigerant level.

Upstairs AC not working: capacitor, coil and drain
Huntington · AC Repair · June 2026
The upstairs system had stopped cooling. A bad capacitor was replaced and the dirty condenser coil cleaned, alongside two cooling tune-ups.

Leaking, frozen system: drain P-trap, TXV and condenser fixed
Deer Park · AC Repair · June 2026
Water leaking from the heating and cooling unit and no cooling. The drain had no P-trap, the TXV needed fixing and the condenser was dirty.

Gas boiler, central air and attic ductwork replaced together
Dix Hills · AC & Heating Installation · June 2026
A combined change-out: the old gas boiler, the attic air handler and outdoor unit, and the old ductwork were all replaced, with new grilles and Wi-Fi thermostats.

Two cooling systems: a failed capacitor and a thermostat that stopped calling
St. James · AC Repair · May 2026
One system was not cooling at all and another was not responding. A new capacitor fixed one, and reprogramming the thermostat fixed the other.

Mini-split not cooling with a flashing light: filters and coil cleaned
Babylon · Mini-Split Service · May 2026
A three-year-old mini-split was not cooling and flashing its operation light. Dirty filters and a dirty outdoor coil were cleaned; refrigerant was good.

Two old systems replaced with a Daikin multi-zone mini-split heat pump
Huntington · Mini-Split Installation · May 2026
Two old indoor air handlers and outdoor units were removed and replaced with a Daikin multi-zone mini-split heat pump, plus a new drain pump.

No hot water: a blocked water heater vent cleared
Huntington Station · Water Heater Repair · May 2026
No hot water from a brand-new water heater. An empty snack bag was blocking the outside vent; we removed it, restarted the heater and tuned up the cooling.

Leaking mini-split: drain line cleared and outdoor coil cleaned
Commack · Mini-Split Service · May 2026
A mini-split was leaking water indoors. The drain line was not draining; we cleared it with nitrogen and chemically cleaned the outdoor unit.

Cooling tune-up on two mini-splits and central air
Kings Park · AC Tune-Up · April 2026
A spring cooling tune-up on a home with two ductless mini-split units and a central air system.

AC not working: new contactor and a deep condenser coil clean
Farmingdale · AC Repair · April 2026
The air conditioner was not working. We replaced the contactor and chemically cleaned the condenser coil with the jacket removed.

Spring AC maintenance with a 70/10 capacitor replaced
Huntington · AC Tune-Up · April 2026
Spring maintenance on the central air, with the capacitor flagged on an earlier visit replaced and a very dirty condenser coil cleaned.

Leaking boiler: expansion tank and air bleeder replaced, plus a tune-up
Dix Hills · Boiler Repair · March 2026
A leaking boiler. We replaced the expansion tank and the air bleeder, bled the air from the system and did the yearly boiler maintenance.

Heat stuck at 63: baseboard fins cleaned, three air bleeders replaced
Huntington · Heating Repair · January 2026
The heat was on but the house only reached 63. Dust-packed baseboard fins and three leaking air bleeders were the cause.

Boiler inspection and performance evaluation before a home sale
Deer Park · Boiler Inspection · December 2025
A boiler inspection and performance evaluation for a home being sold, with a written report and recommendations.

No heat: failed furnace control board and igniter replaced
Commack · Furnace Repair · December 2025
A no-heat call. The furnace control board was not powering the inducer and blower. We replaced the board and the igniter and cleaned the coil.

Zone valve, expansion tank and air vent replaced on an aging boiler
Deer Park · Boiler Repair · December 2025
An aging boiler needed a zone valve. We replaced the whole zone valve assembly, the expansion tank and the air vent, and cleaned the burners.

No heat in one unit: thermostat and leaking air bleeder replaced
Islip · Boiler Repair · November 2025
No heat in one unit of a multi-unit home. We replaced a failed thermostat and a leaking air bleeder and tuned up the four-zone boiler.

Steam boiler tune-up, expansion tank and air bleeder replaced
Deer Park · Boiler Tune-Up · October 2025
The first visit of a new service agreement: a steam boiler tune-up, a new expansion tank for the hot water heater and a new air bleeder.

Expansion tank, relief valve and air bleeder replaced
Woodbury · Boiler Repair · October 2025
During a fall maintenance visit, the technician found a worn expansion tank, relief valve and air bleeder. All three were replaced on a return visit.

AC overflowing and frozen: drain sealed, TXV bulb insulated
Dix Hills · AC Repair · August 2025
Water in the overflow pan and a frozen coil. An open drain connection and a poorly insulated TXV sensor were fixed, and the condenser cleaned.